Materials and methods
Thirty calvaria defects created in 5 rabbits and grafted with both radiolucent (RL, n = 15) and radiopaque (RO, n = 15) bone substitute materials were evaluated, 8 weeks postoperatively. The defects were scanned by multislice computed tomography (Somatom®, Siemens Healthineers, Erlangen, Germany) and CBCT (NewTom VG®, Qualitative Radiology, Verona, Italy). MSCT and CBCT scans were matched to select the exact region of interest (ROI, diameter = 5 mm and height = 1 mm). HU/CT and GV/CBCT of each ROI were obtained. Mean amount of NBF in whole of the defects was measured using serial histomorphometric assessment. We investigated the correlation between HU/CT and GV/CBCT, HU/CT and NBF, and GV/CBCT and NBF generally, and separately among the RL or RO grafted defects, by linear generalized estimating equation modeling. Receiver operation characteristic analysis was performed to check the accuracy of HU/CT and GV/CBCT in diagnosing more than 10% NBF in the samples.